Ultrasonic Phased Array
Product Name : Ultrasonic Phased Array
Details :
veo 16:64 Specification
Phased Array
- Configuration 16:64 (16 pulser/receivers; driving up to 64 elements)
- Transducer Socket I-PEX
- Pulse Voltage -50 V to 100 V (in steps of 10 V)
Data Acquisition
- Architecture Full digital delay and sum architecture
- Digitizing Frequency 50/100 MHz
- Digitizer Resolution 12 bits
- Data Processing 16 bits samples
- Data recording Full raw data recorded
- Max A-Scan Length 8192 samples (32 metres in steel LW, 50MHz, 1:128)
Scan & Views
- Supported Scans S-Scan & L-Scan
- Real Time Views S, L, B, C-Scan, Top and End view
- Colour Maps 8 Standards (Rainbow, Grayscale, Spectrum, Aeronautic or custom)
- Multi Group Multiple Sector scans and TFOD
- CONVENTIONAL UT/TOFD (MONO ELEMENT CHANNELS)
- No. of Channels 2 TX/RX (2 multiplexed channels)
- Test Mode Pulse-Echo, transmit/receive, TOFD
Receivers
- Gain Range 102dB (-30dB to 72dB)
- Filter Bands Narrow bands centred at 0.5 MHz, 1 MHz, 2.25 MHz 5 MHz, 10 MHz and 15 MHz; Broadband at 1 MHz to 18 MHz (-6dB)
- CONVENTIONAL AND PHASED ARRAY
DAC
- DAC Quantity 1 with 3 sub-DAC (per focal law in PA)
- Time Corrected Gain (TCG)
Gates
- A-Scan Gates 4 gates per A-scan (3 extracted A-scans per S/L-scan)
- Gate Trigger Flank/Peak
- S/L-Scan 2 “2D gates” per S/L-scan
- Alarm LED 1 (sync on all gates & DACs)
- Measurements Available in A-Scan view
- 1D Peak (FSH, dB, D, BPL, SD)
- 1D Flank (FSH, dB, D, BPL, SD)
- Echo to Echo
Brochure :